Skip to main content

Process & Industrial Chemistry

Turn reaction understanding into safer, more transferable process decisions.

Status: Proposed capability · subject to evidence gates

Current boundary: Illustrative proposed experiment envelope. This is not performed work, a protocol, an installed capability, a service offer, a validated method or evidence of an operating laboratory. No GMP, GLP, manufacturing-licence, clinical or regulatory-readiness status is claimed.

Technical explanation

• A future process-chemistry environment could connect reaction kinetics, thermodynamics, mixing, heat and mass transfer, impurity formation, crystallisation and process safety around a defined development decision.

• Batch, semi-batch, flow and external-manufacture routes would be compared against the same product, hazard, evidence and economic boundary. A faster route would not be preferred if it weakened control, isolation, waste performance or future transfer.

In everyday terms

• Making a compound consistently is different from making it once. Scientists need to understand where heat goes, what unwanted material can form and how the process responds when conditions change.

• The proposed laboratory would test which route deserves further work and which should change, remain with a specialist or stop.

Published experiment · Video S1

Watch the streams meet.

In this published dye-and-water test, channels repeatedly split and recombine the liquid. It makes contact between streams visible before a process team asks about reaction control, product quality or scale.

What would prove that your reaction is mixed consistently?

Dye and distilled water · passive micromixing array · small experimental device

A four-channel asymmetric split-and-recombine array, fabricated using xurography and lamination, tested with food-colour additive and distilled water. The original title card is retained; the experimental segment is labelled Speed 8x.

Martínez-López et al. (2017). Rapid Fabrication of Disposable Micromixing Arrays Using Xurography and Laser Ablation. Micromachines, 8(5), 144. Video S1 · CC BY 4.0 · Original supplementary source.

The video shows the researchers’ dye/water device. It establishes no reaction conversion, pharmaceutical product quality, industrial readiness or NEUVIOR installation. Its university identity denotes the source, without implying endorsement.

Published caption and reproduction details

Micromixing test of a four channel split and recombine array.

Author-deposited MP4 reproduced byte-for-byte. Full title card, frame and source timing retained; no upscaling.

The poster is a frame from this same experiment.

Illustrative enquiry model

Illustrative batch-to-flow route comparison

Question: For a benign representative transformation, which operating window gives the most controlled conversion, impurity profile, thermal margin and material efficiency?

Variables

• Temperature and residence time

• Feed ratio and concentration

• Mixing or flow regime

• Quench and isolation strategy

Observations

• Reaction and heat-release rate

• Conversion and impurity trajectory

• Pressure and mixing response

• Yield, solvent, water and energy balance

Controls

• Risk-assessed non-energetic model chemistry

• Calibrated material balance

• Defined analytical method state

• HAZOP-style deviation challenge before scale

Decision informed: Select a bounded development route, request specialist work, redesign the chemistry or stop before equipment and scale commitments.

Scientific model and assumptions

Kinetic and transport screening

Model: r = k₀e^(-Eₐ/RT)∏Cᵢ^αᵢ · Da = kC₀^(n-1)τ

Assumptions

• A stated rate-law form is suitable only within the tested domain

• Temperature and composition are measured with known uncertainty

• Transport limitations are assessed rather than assumed absent

Interpretation: The first expression relates reaction rate to temperature and composition. The Damköhler number compares reaction and residence timescales; neither predicts a safe plant without physical evidence and process-safety review.

Indicative equipment and dependencies

Reaction calorimeter

Role: Measure heat-flow and accumulation behaviour under a defined development study.

Dependencies

• Qualified operator

• Safe relief and quench philosophy

• Technique-appropriate ventilation

Parallel stirred-reactor platform

Role: Compare a controlled variable space at development scale.

Dependencies

• Containment based on hazard

• Traceable dosing

• Controlled cleaning and waste

Modular flow-reactor skid

Role: Evaluate residence time, mixing and heat-transfer hypotheses.

Dependencies

• Pressure-rated components

• Interlocks

• Verified material compatibility

In-line FTIR or Raman PAT

Role: Observe selected reaction or composition changes without treating one signal as complete truth.

Dependencies

• Reference strategy

• Model version control

• Independent confirmation

On-line or at-line HPLC

Role: Characterise conversion and impurity trends for the stated analytical purpose.

Dependencies

• Target profile

• Standards custody

• Data review and solvent route

Data and human authority

Data layer

• Time-aligned process and analytical records

• Versioned kinetic models

• Material and energy balance

• Deviation and intervention log

Human authority: The accountable process chemist and process-safety lead approve the experimental domain, interpret uncertainty and decide whether any route advances.

Prohibited automation: No model or robot may expand the chemical, pressure, temperature or hazard envelope, approve scale-up or declare a process safe.

Potential output and stop condition

Potential output: A development-route recommendation with kinetic evidence, impurity risks, thermal boundaries, sustainability measures and unresolved scale questions.

Stop gate: Stop or transfer when hazard, control, isolation, waste, data quality, expertise or economics cannot support another internal cycle.

Campus design implications

Constellation is one developing campus concept. Scotland is among the locations under consideration; the programme does not currently present a second committed campus in India or elsewhere.

A capability brief before a location decision

High-value process development linked to analytical science, advanced manufacturing and regional precision engineering.

Process understanding for formulations, generics, intermediates and future cross-border technology transfer.

Design for the chosen site and its users

Enclosed modular cells, strong heat-recovery logic and clear separation of chemistry, analytical and servicing routes.

Heat-, water- and power-aware utilities with shaded servicing, segregated solvent routes and phased pilot optionality.

These are alternative requirements to test against climate, product scope, users and the local operating route. They describe a design brief, rather than installed equipment, available services or an approved building.

The investment question

Could help product teams expose scale and transfer risk before larger external or capital commitments.

Could connect cross-border chemistry knowledge to clearer analytical and future manufacturing transfer packages.

Potential users

Type: Pharmaceutical and biotechnology teams

Need: A development route for a defined compound or intermediate question.

Proposed deliverable: A scoped process-knowledge and transfer-risk package.

Type: Universities and spin-outs

Need: Translation from a research reaction to a reproducible development question.

Proposed deliverable: A governed feasibility study with rights, hazards and next gates visible.

Type: CDMOs and engineering partners

Need: Earlier visibility of material, process and analytical assumptions.

Proposed deliverable: A receiving-party gap assessment rather than a fictional ready-to-scale process.

Sustainability questions

Metric: Process mass intensity

Method: Total input mass, including water and solvents, divided by isolated product mass for the stated boundary.

Decision informed: Compare routes without assuming flow or automation is inherently greener.

Metric: Solvent and water route

Method: Record purchase, use, segregation, recovery feasibility and authorised disposal by material class.

Decision informed: Select chemistry, equipment and externalisation routes on measured burden.

Metric: Energy per decision

Method: Submeter reaction, separation and analytical energy for a completed evidence gate.

Decision informed: Avoid optimising reaction time while hiding downstream energy demand.

Safety and regulatory gates

• Documented chemical and process-hazard assessment

• Defined prohibited chemistry and operating envelope

• COSHH or applicable Indian chemical-safety controls

• Compatible containment, relief, effluent and authorised waste routes

• Independent scale-up and operator review before any larger activity

Sources and scientific attribution

ICH Q13 continuous manufacturing

Source type: Official framework

Relevance: Defines concepts and regulatory considerations for continuous manufacture of drug substances and products.

Caveat: It does not select a process, establish safety or show NEUVIOR compliance.

Source: https://database.ich.org/sites/default/files/ICH_Q13_Step4_Guideline_2022_1116.pdf

Innovate UK: Medicines Manufacturing - Labs of the Future

Source type: Official programme

Relevance: Provides current UK policy context for digital, automated and robotic medicines process development and manufacturing innovation.

Caveat: A competition scope is not evidence of a NEUVIOR campus application or award, or that NEUVIOR has developed the technologies described. NEUVIOR's separate funded-project record is stated in the evidence hub.

Source: https://apply-for-innovation-funding.service.gov.uk/competition/2417/overview/5ec76f19-8bd0-4dfa-b869-f4f0401448de/

ACS process mass intensity calculation tool

Source type: Official programme

Relevance: Provides a common pharmaceutical material-efficiency metric.

Caveat: PMI alone does not measure toxicity, carbon, water stress or whole-life impact.

Source: https://www.acs.org/green-chemistry-sustainability/green-chemistry-nexus/articles/process-mass-intensity-calculation-tool.html

NEWSPerspectives & features